[HTML][HTML] Effect of different embolization materials on proton beam stereotactic radiosurgery Arteriovenous Malformation dose distributions using the Monte Carlo …
… As a result of the calculations; We suggest that the embolization material should be chosen
whichever is more important from Bragg peak position/amplitude, recoils or lateral scattering …
whichever is more important from Bragg peak position/amplitude, recoils or lateral scattering …
[HTML][HTML] Dosimetric effects of embolization material artefacts in arteriovenous malformations stereotactic radiosurgery on treatment planning calculation
A Elawadi, M Alshanqity, H AlHussain… - … Imaging in Radiation …, 2022 - Elsevier
… that the pencil beam (PB) dose calculation algorithm overestimates the calculated dose. …
dosimetric effects of the embolic materials on the AVM treatment planning dose calculations in …
dosimetric effects of the embolic materials on the AVM treatment planning dose calculations in …
Stereotactic radiosurgery alone or combined with embolization for brain arteriovenous malformations: a systematic review and meta-analysis
… overall impact of embolic material confounding radiosurgical … of effect between the different
types of embolic materials on … AVM following embolization with Onyx: possible dosage error …
types of embolic materials on … AVM following embolization with Onyx: possible dosage error …
Effect of embolization before stereotactic radiosurgery for brain arteriovenous malformations: a case-control study with propensity score matching
T Hasegawa, T Kato, T Naito, A Mizuno… - Journal of …, 2022 - thejns.org
… that pre-SRS embolization had a negative impact on nidus … using the formula of XYZ/2 on
DSA before embolization.In … that pre-SRS embolization makes dose planning more difficult and …
DSA before embolization.In … that pre-SRS embolization makes dose planning more difficult and …
Stereotactic radiosurgery for arteriovenous malformations: the effect of treatment period on patient outcomes
BE Pollock, MJ Link, SL Stafford, YI Garces… - Neurosurgery, 2016 - journals.lww.com
… , dose planning was based on a combination of stereotactic … our early practice underwent
embolization to reduce the nidus … Conformality indices have not been routinely calculated in …
embolization to reduce the nidus … Conformality indices have not been routinely calculated in …
[HTML][HTML] … safety of combined endovascular embolization and stereotactic radiosurgery for patients with intracranial arteriovenous malformations: a systematic review …
Z Jiang, X Zhang, X Wan, M Wei, Y Liu… - BioMed Research …, 2021 - hindawi.com
… effects of prior embolization in patients with IAVMs could be affected by nidus volume,
margin dose… Subsequently, the pooled effect estimates were calculated using the random-effects …
margin dose… Subsequently, the pooled effect estimates were calculated using the random-effects …
The impact of embolization on radiosurgery obliteration rates for brain arteriovenous malformations: a systematic review and meta‐analysis
… the impact of pre-stereotactic radiosurgery (SRS) embolization … mean or median margin
dose, embolic agent used, percent … , favoring SRS without embolization, was calculated by meta-…
dose, embolic agent used, percent … , favoring SRS without embolization, was calculated by meta-…
The role of biological effective dose in predicting obliteration after stereotactic radiosurgery of cerebral arteriovenous malformations
CL Nesvick, CS Graffeo, PD Brown, MJ Link… - Mayo Clinic …, 2021 - Elsevier
… Biological effective dose was calculated using a mono-… the impact of different clinical and
radiosurgical parameters … AVM with no previous radiation or embolization. A minimum of 2 …
radiosurgical parameters … AVM with no previous radiation or embolization. A minimum of 2 …
[HTML][HTML] Linac-based stereotactic radiosurgery for brain arteriovenous malformations
A Gawish, B Röllich, HJ Ochel, TB Brunner - Radiation Oncology, 2022 - Springer
… noted that prior embolization had no effect on the obliteration … to achieve high doses of
radiation with steep dose gradients and … As a result, the standard formula was employed to allow …
radiation with steep dose gradients and … As a result, the standard formula was employed to allow …
Stereotactic radiosurgery for brain arteriovenous malformations: evaluation of obliteration and review of associated predictors
BJ Daou, G Palmateer, BG Thompson… - Journal of Stroke and …, 2020 - Elsevier
… a median radiation dose of 16 Gy. Complete AVM obliteration was achieved in 80.3%. …
AVMs chosen for pre-SRS embolization and the effects that embolization could have on radiation …
AVMs chosen for pre-SRS embolization and the effects that embolization could have on radiation …